skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Fleischman, Robert_B"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. ABSTRACT This study integrates analytical and experimental research to develop an innovative shake table testing method called Floor Acceleration Simulation Test (FAST). The primary objective of FAST is to produce an essentially elastic response of a single‐story test specimen to replicate the floor acceleration time history including higher‐mode effects of a target floor in a multistory building experiencing inelastic behavior during an earthquake. The FAST method is well suited for experimental research where the absolute accelerations and the associated inertial forces of the floor diaphragms cannot be simulated by the majority of the conventional test methods. The proposed methodology is based on a transfer function in the frequency domain to compute the required input motion for testing. Considering the physical constraints of a given shake table test facility, guidelines with two response spectra to bracket the natural frequency of the test building are also presented for practical implementation. Experimental validation was carried out on a half‐scale, single‐story steel building featuring a composite floor slab, utilizing the NHERI@UCSD Large High‐Performance Outdoor Shake Table (LHPOST) facility. The results demonstrate the effectiveness of FAST, as both analytical predictions and experimental outcomes confirm its validity. Despite instances of measured floor acceleration amplitude exceeding the target response due to table input motion overshooting in this test program, test results confirmed that the FAST accurately reproduced the intended frequency content, indicative of higher mode effects in the multistory prototype building, in the single‐story test building. 
    more » « less